自动门维修注意事项
自动门维修注意事项
Matters needing attention in automatic door maintenance
1、感应自动门报警功能的性能取决于报警探头的性能用户应根据报警的实际需要选配报警探头。DKM-2B控制器成套出厂时配一只热释型报警探头。如果不用报警功能探头不椄即可。
1. The performance of the alarm function of the induction automatic door depends on the performance of the alarm probe, and the user should select the alarm probe according to the actual needs of the alarm. The DKM-2B controller is equipped with a pyroelectric alarm probe when it is factory. If no alarm probe can not Jie.
2、自动门报警探头输出信号接口的类型应为继电器输出接口供电电压应为直流12-15V否则不能由本控制器直接供电。探头耗电应100毫安。根据现场情况可配用多只探头(一般以1――2只为宜)多探头时采用并接方式。探头。应避免其他热源或直射光影响上方应加防雨罩。
2, the automatic gate alarm probe output signal interface type should be the output interface of the relay, the power supply voltage should be DC 12-15V, otherwise it can not be directly powered by the controller. Probe power consumption should be 100 ma. According to the field situation, more than one probe can be used (usually 1 - 2 is appropriate). Probe. Should avoid other heat source or direct light influence, should add rainproof cover above.
3、感应自动门自动停机功能可根据用户的门体行程设置出厂时设定为145秒左右。
3. The automatic stop function of induction automatic door can be set according to the door travel of the user, and it is set to be about 145 seconds when the factory is set.
4、发现自动门开门和关门方向相反时将控制器的端子接线对调即可。同样STOP显示屏指示方向与实际相反时按同法调整接线。
4, find the automatic door opening and closing direction opposite, the controller terminal connection can be switched. Similarly, when the direction of the STOP display direction is opposite to the actual situation, the wiring is adjusted according to the same method.